Number of channels |
Channel 4-16 |
Sensors |
Type K thermocouple |
Accuracy |
0.5 degrees |
|
Heat insulation box |
300 degrees ,60 minutes ,500 degrees 600 minutes |
Instrument measuring range |
-200-1370℃ |
|||
Memory |
Oversized memory can record 200,000 data |
|||||
Sampling rate |
0.05,0.1,0.2,0.5,1s ,2s ,3s ,4s ,5s ,6s ,10s ,20s, etc. |
|||||
Computer Requirements |
Windows 98,2000, XP, win7, win8, win10, etc. |
|||||
Features of Instruments and Software |
1, Can be tested 20 times, data 1 download 2, USB port for all computers 3, When data is downloaded, the instrument recharges itself 4, Standard voltage calibration, reliable precision 5, One-click, easy to learn and use 6, Calculate the rise time and slope of the multi-temperature section 7, Calculate the holding time above any temperature point |
8, The software has the function of intelligent warning, testing the curve to determine whether the furnace temperature is up to standard. 9, Can intercept the curve of any time period for analysis 10, Curve magnification is more practical 11, Any temperature line can be drawn on the curve 12, Detailed report printing function 13, Report can generate image save |
||||
Insulation box |
300 degrees 60 min 10 x 14 x 28 cm 、500 min 60 min 12 x 15 x 28 cm |
|||||
Standard configuration |
l Temperature Recorder l Temperature line (paste, magnet, clamp) l Communication line l Data Downloading and Analysis Software l scissors l Instrument box |